Zhongshan Shangfang Instrument Meter Co., Ltd.

home products Digital temperature controller Electronic Temperature Controller ED108

Electronic Temperature Controller ED108

Product Details:

Usage refrigeration
Theory Temperature Controller
Place of Origin Guangdong, China
Brand Name Shangfang
Model Number ED108

Payment & Shipping Terms:

Minimum Order Quantity: 100 Piece/Pieces
Packaging Details: 50pcs/standard export carton, carton size:49.5x43.5x18.5cm
Delivery Time: 10 days
Payment Terms: L/C,T/T
Supply Ability: 200000 Piece/Pieces per Month

Detailed Product Description


1. Ideal for fan cooling freezers of low temperature

2. Temperature control

3. Evaporator fan control

4. With built-in transformer / compressor control

5. Manual / automatic defrost by electric heaterhot gas

6. Time / temp. setting to end defrosting

7. High/ low temperature alarm

8. Re-start delay

9. Parameter locking

10. Temperature range:-45 to 100oC(-45 to 150oF)

11. Accuracy: ±1.0oC(±1.8oF)

12. Sensor:NTC, 2pcs (room temperature & defrosting control)

13. Power supply: 230VAC or 120VAC  50/ 60 Hz

14. Compressor:16A/250VAC

15. Defrosting:10A/250VAC

16. Evap.Fan:5A/250VAC

17. Dimension: 77(L)×35(W)×60(D)mm

18. Mounting hole dimension:71(L)×29(W)mm

Paramete
Function
Set range
Default
E1
Lower setpoint limit
-45oC/oF to Set temp.
-31oF/-35oC
E2
Higher setpoint limit
Set temp. to 45oC/113oF
45oC/113oF
E3
Temp.hysteresis
1 to 20.0oC/1.8 to 36.0oF
4.0oC/7.2oF
E4
Comp.start delay time
0 to 10Min
2Min
E5
Offset on room temp.
-20.0 to 20.0oC/-36.0 to 36.0oF
0
E6
Offset on evap.temp.
-20.0 to 20.0oC/-36.0 to 36.0oF
0
F0
Defrost function
0=Electric heater
1=Hot gas
0
F1
Max.Defrost duration
1 to 60Min
20Min
F2
Defrost interval time
0 to 24Hr
6Hr
F3
Defrost termination temp.
0 to 30oC/32 to 68oF
8 oC/46oF
F4
Display during defrost
0=Normal display
1=Last value before defrost
0
F5
Dripping time
0 to 30Min
2Min
F6
Temperature display delay time after defrosting(F4=1)
0 to 60Min
20Min
H1
Fan start delay time after defrosting
0 to 10Min
1Min
H2
Fan operating function
0=Parallel with comp.,close when defrosting
1=Continuous running except defrosting
2=Parallel with comp.,open when defrosting
3=Continuous running except defrosting
4=Start temperature(rests with evap.temp.
5=Start temperature (rests with the temperature in cold-room)
4
H3
Fan start temp.(H2=4,5)
-30 to 30oC/-22 to 86oF
5oC/41oF
H4
Fan delay after time after comopressor stops.(H2=1,2H)
0 to 30Min
0Min
C0
Resolutio
0.1/1  oC/oF
0.1
C1
Temperature unit
0=Celsius   1=Fahrenheit
C
C2
High temperature alarm
C3 to 130oC/ C3 to 130oF
50oC/122oF
C3
Low temperature alarm
-40 to C2 /-40 to C2
-40oC/-40oF
C4
Alarm delay time
1 to 90Min
60Min

Electronic Temperature Controller ED108 Electronic Temperature Controller ED108

Send your message to this supplier
« Prev Product ... 36 37 38 39 40 41 42 ... Next Product »