Electronic Temperature Controller ED108
Product Details:
| Usage | refrigeration |
|---|---|
| Theory | Temperature Controller |
| Place of Origin | Guangdong, China |
| Brand Name | Shangfang |
| Model Number | ED108 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 100 Piece/Pieces |
|---|---|
| Packaging Details: | 50pcs/standard export carton, carton size:49.5x43.5x18.5cm |
| Delivery Time: | 10 days |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 200000 Piece/Pieces per Month |
Detailed Product Description
1. Ideal for fan cooling freezers of low temperature
2. Temperature control
3. Evaporator fan control
4. With built-in transformer / compressor control
5. Manual / automatic defrost by electric heaterhot gas
6. Time / temp. setting to end defrosting
7. High/ low temperature alarm
8. Re-start delay
9. Parameter locking
10. Temperature range:-45 to 100oC(-45 to 150oF)
11. Accuracy: ±1.0oC(±1.8oF)
12. Sensor:NTC, 2pcs (room temperature & defrosting control)
13. Power supply: 230VAC or 120VAC 50/ 60 Hz
14. Compressor:16A/250VAC
15. Defrosting:10A/250VAC
16. Evap.Fan:5A/250VAC
17. Dimension: 77(L)×35(W)×60(D)mm
18. Mounting hole dimension:71(L)×29(W)mm
Paramete | Function | Set range | Default |
E1 | Lower setpoint limit | -45oC/oF to Set temp. | -31oF/-35oC |
E2 | Higher setpoint limit | Set temp. to 45oC/113oF | 45oC/113oF |
E3 | Temp.hysteresis | 1 to 20.0oC/1.8 to 36.0oF | 4.0oC/7.2oF |
E4 | Comp.start delay time | 0 to 10Min | 2Min |
E5 | Offset on room temp. | -20.0 to 20.0oC/-36.0 to 36.0oF | 0 |
E6 | Offset on evap.temp. | -20.0 to 20.0oC/-36.0 to 36.0oF | 0 |
F0 | Defrost function | 0=Electric heater 1=Hot gas | 0 |
F1 | Max.Defrost duration | 1 to 60Min | 20Min |
F2 | Defrost interval time | 0 to 24Hr | 6Hr |
F3 | Defrost termination temp. | 0 to 30oC/32 to 68oF | 8 oC/46oF |
F4 | Display during defrost | 0=Normal display 1=Last value before defrost | 0 |
F5 | Dripping time | 0 to 30Min | 2Min |
F6 | Temperature display delay time after defrosting(F4=1) | 0 to 60Min | 20Min |
H1 | Fan start delay time after defrosting | 0 to 10Min | 1Min |
H2 | Fan operating function | 0=Parallel with comp.,close when defrosting 1=Continuous running except defrosting 2=Parallel with comp.,open when defrosting 3=Continuous running except defrosting 4=Start temperature(rests with evap.temp. 5=Start temperature (rests with the temperature in cold-room) | 4 |
H3 | Fan start temp.(H2=4,5) | -30 to 30oC/-22 to 86oF | 5oC/41oF |
H4 | Fan delay after time after comopressor stops.(H2=1,2H) | 0 to 30Min | 0Min |
C0 | Resolutio | 0.1/1 oC/oF | 0.1 |
C1 | Temperature unit | 0=Celsius 1=Fahrenheit | C |
C2 | High temperature alarm | C3 to 130oC/ C3 to 130oF | 50oC/122oF |
C3 | Low temperature alarm | -40 to C2 /-40 to C2 | -40oC/-40oF |
C4 | Alarm delay time | 1 to 90Min | 60Min |
Electronic Temperature Controller ED108
Other Products from this Supplier
See more
Digital temperature controller, electronic thermostat, intelligent temperature controller products from this supplier.